Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
2.
Article in English | MEDLINE | ID: mdl-38571287

ABSTRACT

INTRODUCTION: Pulmonary vein isolation (PVI) is often performed under general anaesthesia (GA) or deep sedation. Anaesthetic availability is limited in many centers, and deep sedation is prohibited in some countries without anaesthetic support. Very high-power short duration (vHPSD-90W/4 s) PVI using the Q-Dot catheter is generally well tolerated under mild conscious sedation (MCS) though an understanding of catheter stability and long-term effectiveness is lacking. We analyzed lesion metrics and 12-month freedom from atrial arrythmia with this approach. METHODS: Our approach to radiofrequency (RF) PVI under MCS is standardized and includes a single catheter approach with a steerable sheath. We identified patients undergoing Q-Dot RF PVI between March 2021 and December 2022 in our center, comparing those undergoing vHPSD ablation under MCS (90W/MCS) against those undergoing 50 W ablation under GA (50 W/GA) up to 12 months of follow-up. Data were extracted from clinical records and the CARTO system. RESULTS: Eighty-three patients met our inclusion criteria (51 90W/MCS; 32 50 W/GA). Despite shorter ablation times (353 vs. 886 s; p < .001), the 90 W/MCS group received more lesions (median 87 vs. 58, p < .001), resulting in similar procedure times (149.3 vs. 149.1 min; p = .981). PVI was achieved in all cases, and first pass isolation rates were similar (left wide antral circumferential ablation [WACA] 82.4% vs. 87.5%, p = .758; right WACA 74.5% vs. 78.1%, p = .796; 90 W/MCS vs. 50 W/GA respectively). Analysis of 6647 ablation lesions found similar mean impedance drops (10.0 ± 1.9 Ω vs. 10.0 ± 2.2 Ω; p = .989) and mean contact force (14.6 ± 2.0 g vs. 15.1 ± 1.6 g; p = .248). Only median 2.5% of lesions in the 90 W/MCS cohort failed to achieve ≥ 5 Ω drop. In the 90 W/MCS group, there were no procedural related complications, and 12-month freedom from atrial arrhythmia was observed in 78.4%. CONCLUSION: vHPSD PVI is feasible under MCS, with encouraging acute and long-term procedural outcomes. This provides a compelling option for centers with limited anaesthetic support.

3.
Heart Rhythm ; 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38636929

ABSTRACT

BACKGROUND: No study has assessed durability of pulmonary vein isolation (PVI) with radiofrequency (RF) and Cryoballoon (CB) in patients with persistent AF. These data are especially lacking for those with significantly diseased left atria (LA). OBJECTIVE: To assess PVI durability in patients with significant LA disease and compare reconnection rates between RF and CB. METHODS: 44 Patients (mean age 63, 77% male, median time since AF diagnosis 22.5 months, median indexed LA volume 36 ml/m2) were randomised 1:1 to RF (StablePoint catheter, Boston Scientific) or CB (Arctic Front Advance, Medtronic) PVI. A redo procedure using ultra high-density electroanatomic mapping (Rhythmia, Boston Scientific) was mandated at 2 months, where PV reconnections were identified and re-isolated. RESULTS: 38 patients underwent both procedures (n=17 CB, n=21 RF). Index RF procedures were longer (median 158 vs 97min; p<0.001) but required less fluoroscopy (9.5 vs 23min; p<0.001). At the index RF procedure, median 47% of LA myocardium had voltage <0.5mV, suggesting half of the mapped LA comprised scar. PV reconnection was observed in 73/152 (48.0%) PVs and was more frequent with CB (58.8%) vs RF (39.3%), p=0.022. Reconnection of at least 1 PV was detected in >75% of patients. Significantly more ablation was required at redo to reisolate PVs in the CB arm (median 10.8 vs 1.2min; p<0.001). CONCLUSION: PVI durability may be poor in those with significant LA scarring and dilatation, even with modern thermal ablation technologies. RF resulted in significantly better PVI durability than CB in this complex population. CLINICAL TRIAL REGISTRATION: NCT04111731.

6.
Article in English | MEDLINE | ID: mdl-37981202

ABSTRACT

Stroke prevention and symptom control are two integral pillars in atrial fibrillation (AF) management. Percutaneous left atrial appendage occlusion (LAAO) is effective at reducing stroke risk in high-risk patients with AF who cannot tolerate oral anticoagulant therapy, whilst catheter ablation is effective at reducing AF burden and improving quality-of-life in patients who remain symptomatic despite medical therapy. If both procedures are indicated in an individual patient, they have traditionally been performed on separate occasions, due to long cumulative procedural times, itself associated with thromboembolic risk. Recently, with the advancement of procedural techniques, the concept of concurrent LAAO and AF catheter ablation has gained traction. This review summarises the evidence for and against concurrent LAAO and AF catheter ablation, discussing procedural considerations, including procedural sequencing and post-procedural antithrombotic therapy, safety and efficacy outcomes, and future directions in the field.

9.
Br J Cardiol ; 29(2): 12, 2022.
Article in English | MEDLINE | ID: mdl-36212785

ABSTRACT

Ambulatory electrocardiogram (AECG) monitoring is a common cardiovascular investigation. Traditionally, this requires a face-to-face appointment. In order to reduce contact during the COVID-19 pandemic, we investigated whether drive-by collection and self-fitting of the device by the patient represents an acceptable alternative. A prospective, observational study of consecutive patients requiring AECG monitoring over a period of one month at three hospitals was performed. Half underwent standard (face-to-face) fitting, and half attended a drive-by service to collect their monitor, fitting their device at home. Outcome measures were quality of the recordings (determined as good, acceptable or poor), and patient satisfaction. A total of 375 patients were included (192 face-to-face, 183 drive-by). Mean patient age was similar between the two groups. The quality of the AECG recordings was similar in both groups (52.6% good in face-to-face vs. 53.0% in drive-by; 34.9% acceptable in face-to-face vs. 32.2% in drive-by; 12.5% poor in face-to-face vs. 14.8% in drive-by; Chi-square statistic 0.55, p=0.76). Patient satisfaction rates were high, with all patients in both groups satisfied with the care they received. In conclusion, drive-by collection and self-fitting of AECG monitoring yields similar AECG quality to conventional face-to-face fitting, with high levels of patient satisfaction.

10.
Br J Hosp Med (Lond) ; 83(3): 1-11, 2022 Mar 02.
Article in English | MEDLINE | ID: mdl-35377207

ABSTRACT

Infective endocarditis is a rare but deadly disease, with a highly variable presentation. The clinical manifestations of the condition are often multisystemic, ranging from dermatological to ophthalmic, and cardiovascular to renal. Thus, patients with infective endocarditis may first present to the acute or general physician, who may have a variable knowledge of the condition. The diagnosis of infective endocarditis can be challenging, relying on clinical, imaging and microbiological features. Recent decades have seen a transformation in the epidemiology and microbiology of infective endocarditis and yet, despite advances in diagnostics and therapeutics, mortality rates remain high. This review outlines the emerging studies and guidelines on the assessment and management of infective endocarditis, focusing on the evolving epidemiology of the condition, the role of new imaging modalities, updated diagnostic criteria, the latest on antimicrobial and surgical management, and the role of a multidisciplinary approach in the management of patients with infective endocarditis.


Subject(s)
Anti-Infective Agents , Endocarditis, Bacterial , Endocarditis , Anti-Bacterial Agents/therapeutic use , Endocarditis/diagnosis , Endocarditis/epidemiology , Endocarditis/therapy , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/epidemiology , Endocarditis, Bacterial/therapy , Heart , Humans
11.
Br J Neurosurg ; 36(5): 643-646, 2022 Oct.
Article in English | MEDLINE | ID: mdl-30475069

ABSTRACT

A 65 year-old lady with metastatic breast cancer presented with pituitary apoplexy. Following surgery, histopathology confirmed metastatic breast carcinoma into a gonadotroph cell adenoma of the pituitary. Tumours that metastasise to a normal pituitary gland are unusual. More so, such neoplasm-to-neoplasm metastasis is extremely rare. This is, as far as we are aware, the first description of a metastasis into a gonadotroph cell pituitary adenoma presenting as apoplexy.


Subject(s)
Adenoma , Breast Neoplasms , Gonadotrophs , Pituitary Apoplexy , Pituitary Neoplasms , Female , Humans , Aged , Pituitary Apoplexy/complications , Pituitary Neoplasms/complications , Gonadotrophs/pathology , Adenoma/complications , Adenoma/diagnostic imaging , Adenoma/surgery , Magnetic Resonance Imaging , Pituitary Gland/surgery , Breast Neoplasms/complications , Breast Neoplasms/pathology
12.
Med J Aust ; 215(11): 529-531, 2021 Dec 13.
Article in English | MEDLINE | ID: mdl-34897725

ABSTRACT

•In view of his advanced age and risk factors, Santa Claus is at high risk of developing atrial fibrillation. Despite this, no guidelines exist on the subject. •Following a review of the literature, we present our position on the management of atrial fibrillation in Santa Claus, and propose the use of the SANTA CLAUS mnemonic to aid clinicians: Screen for atrial fibrillation; Anticoagulate; Normalise heart rate; Treat comorbidities; Anti-arrhythmic drugs; Cardioversion; Lifestyle measures; Ablation treatment; Understand emotional and psychological impact; Save Santa Claus.


Subject(s)
Atrial Fibrillation/therapy , Age Factors , Aged, 80 and over , Atrial Fibrillation/diagnosis , Critical Pathways , Humans , Male , Wit and Humor as Topic
13.
Front Cardiovasc Med ; 8: 735008, 2021.
Article in English | MEDLINE | ID: mdl-34746253

ABSTRACT

The current management of acute coronary syndromes (ACS) is with an invasive strategy to guide treatment. However, identifying the lesions which are physiologically significant can be challenging. Non-invasive imaging is generally not appropriate or timely in the acute setting, so the decision is generally based upon visual assessment of the angiogram, supplemented in a small minority by invasive pressure wire studies using fractional flow reserve (FFR) or related indices. Whilst pressure wire usage is slowly increasing, it is not feasible in many vessels, patients and situations. Limited evidence for the use of FFR in non-ST elevation (NSTE) ACS suggests a 25% change in management, compared with traditional assessment, with a shift from more to less extensive revascularisation. Virtual (computed) FFR (vFFR), which uses a 3D model of the coronary arteries constructed from the invasive angiogram, and application of the physical laws of fluid flow, has the potential to be used more widely in this situation. It is less invasive, fast and can be integrated into catheter laboratory software. For severe lesions, or mild disease, it is probably not required, but it could improve the management of moderate disease in 'real time' for patients with non-ST elevation acute coronary syndromes (NSTE-ACS), and in bystander disease in ST elevation myocardial infarction. Its practicability and impact in the acute setting need to be tested, but the underpinning science and potential benefits for rapid and streamlined decision-making are enticing.

14.
Br J Hosp Med (Lond) ; 82(9): 1-4, 2021 Sep 02.
Article in English | MEDLINE | ID: mdl-34601928

ABSTRACT

In 2021 the National Institute for Health and Care Excellence updated its guidance for diagnosing and managing atrial fibrillation. This editorial summarises the key changes made in these guidelines and discusses their implementation in UK clinical practice.


Subject(s)
Atrial Fibrillation , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Humans
16.
Wellcome Open Res ; 6: 73, 2021.
Article in English | MEDLINE | ID: mdl-34095509

ABSTRACT

Background: Four-dimensional (4D) flow cardiovascular magnetic resonance imaging (MRI) is an emerging technique used for intra-cardiac blood flow assessment. The role of 4D flow cardiovascular MRI in the assessment of trans-valvular flow in patients with atrial fibrillation (AF) has not previously been assessed. The purpose of this study was to assess the feasibility, image quality, and internal validity of 4D flow cardiovascular MRI in the quantification of trans-valvular flow in patients with AF. Methods: Patients with AF and healthy controls in sinus rhythm underwent cardiovascular MRI, including 4D flow studies. Quality assurance checks were done on the raw data and streamlines. Consistency was investigated by trans-valvular flow assessment between the mitral valve (MV) and the aortic valve (AV). Results: Eight patients with AF (88% male, mean age 62±13 years, mean heart rate (HR) 83±16 beats per minute (bpm)) were included and compared with ten healthy controls (70% male, mean age 41±20 years, mean HR 68.5±9 bpm). All scans were of either good quality with minimal blurring artefacts, or excellent quality with no artefacts. No significant bias was observed between the AV and MV stroke volumes in either healthy controls (-4.8, 95% CI -15.64 to 6.04; P=0.34) or in patients with AF (1.64, 95% CI -4.7 to 7.94; P=0.56). A significant correlation was demonstrated between MV and AV stroke volumes in both healthy controls (r=0.87, 95% CI 0.52 to 0.97; P=0.001) and in AF patients (r=0.82, 95% CI 0.26 to 0.97; P=0.01). Conclusions: In patients with AF, 4D flow cardiovascular MRI is feasible with good image quality, allowing for quantification of trans-valvular flow.

18.
Eur Heart J Case Rep ; 5(2): ytaa529, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33569526

ABSTRACT

BACKGROUND: Cardiac involvement in Anderson-Fabry disease (AFD) can lead to arrhythmia, including ventricular tachycardia (VT). The literature on radiofrequency ablation (RFA) for the treatment of VT in AFD disease is limited. CASE SUMMARY: We discuss RFA of drug-refractory VT electrical storm in three males with AFD. The first patient (53 years old) had extensive involvement of the inferolateral left ventricle (LV) demonstrated with cardiac magnetic resonance imaging (CMRI), with a left ventricular ejection fraction (LVEF) of 35%. Two VT ablation procedures were performed. At the first procedure, the inferobasal endocardial LV was ablated. Furthermore, VT prompted a second ablation, where epicardial and endocardial sites were ablated. The acute arrhythmia burden was controlled but he died 4 months later despite appropriate implantable cardioverter-defibrillator therapies for VT. The second patient (67 years old) had full-thickness inferolateral involvement demonstrated with CMRI and LVEF of 45%. RFA of several endocardial left ventricular sites was performed. Over a 3-year follow-up, only brief non-sustained VT was identified, but he subsequently died of cardiac failure. Our third patient (69 years old), had an LVEF of 35%. He had RFA of endocardial left ventricular apical disease, but died 3 weeks later of cardiac failure. DISCUSSION: RFA of drug-refractory VT in AFD is feasible using standard electrophysiological mapping and ablation techniques, although the added clinical benefit is of questionable value. VT storm in the context of AFD may be a marker of end-stage disease.

20.
J Am Coll Cardiol ; 75(20): 2538-2549, 2020 05 26.
Article in English | MEDLINE | ID: mdl-32439003

ABSTRACT

BACKGROUND: Coronary microvascular dysfunction (CMD) is defined by diminished flow reserve. Functional and structural CMD endotypes have recently been described, with normal and elevated minimal microvascular resistance, respectively. OBJECTIVES: This study determined the mechanism of altered resting and maximal flow in CMD endotypes. METHODS: A total of 86 patients with angina but no obstructive coronary disease underwent coronary pressure and flow measurement during rest, exercise, and adenosine-mediated hyperemia and were classified as the reference group or as patients with CMD by a coronary flow reserve threshold of 2.5; functional or structural endotypes were distinguished by a hyperemic microvascular resistance threshold of 2.5 mm Hg/cm/s. Endothelial function was assessed by forearm blood flow (FBF) response to acetylcholine, and nitric oxide synthase (NOS) activity was defined as the inverse of FBF reserve to NG-monomethyl-L-arginine. RESULTS: Of the 86 patients, 46 had CMD (28 functional, 18 structural), and 40 patients formed the reference group. Resting coronary blood flow (CBF) (24.6 ± 2.0 cm/s vs. 16.6 ± 3.9 cm/s vs. 15.1 ± 4.7 cm/s; p < 0.001) and NOS activity (2.27 ± 0.96 vs. 1.77 ± 0.59 vs. 1.30 ± 0.16; p < 0.001) were higher in the functional group compared with the structural CMD and reference groups, respectively. The structural group had lower acetylcholine FBF augmentation than the functional or reference group (2.1 ± 1.8 vs. 4.1 ± 1.7 vs. 4.5 ± 2.0; p < 0.001). On exercise, oxygen demand was highest (rate-pressure product: 22,157 ± 5,497 beats/min/mm Hg vs. 19,519 ± 4,653 beats/min/mm Hg vs. 17,530 ± 4,678 beats/min/mm Hg; p = 0.004), but peak CBF was lowest in patients with structural CMD compared with the functional and reference groups. CONCLUSIONS: Functional CMD is characterized by elevated resting flow that is linked to enhanced NOS activity. Patients with structural CMD have endothelial dysfunction, which leads to diminished peak CBF augmentation and increased demand during exercise. The value of pathophysiologically stratified therapy warrants investigation.


Subject(s)
Angina Pectoris/diagnosis , Coronary Vessels/physiopathology , Microcirculation , Adenosine/chemistry , Aged , Angina Pectoris/physiopathology , Biomarkers/metabolism , Blood Flow Velocity , Coronary Angiography , Coronary Artery Disease/physiopathology , Coronary Circulation , Endothelium, Vascular/metabolism , Exercise , Female , Humans , Hyperemia/metabolism , Male , Middle Aged , Myocardial Ischemia/physiopathology , Nitric Oxide Synthase/metabolism , Plethysmography , Reference Values
SELECTION OF CITATIONS
SEARCH DETAIL
...